Product Overview
Euwoo Metal Door Frames are engineered to provide the essential structural support for commercial door openings. Manufactured from high-quality cold-rolled or galvanized steel, our frames meet the rigorous demands of HMMA and SDI standards.
Whether for new construction requiring robust welded frames or renovation projects needing flexible knock-down solutions, we offer comprehensive configurations. With fire ratings up to 3 hours and gauges from 18 to 12, our frames ensure code compliance and long-term durability in any environment.
Applications
Metal door frames for commercial and institutional buildings
Commercial Buildings
Steel frames for office buildings and retail centers.
- • Fire ratings available
- • Durable construction
- • Custom sizes
Config: 16 gauge, Welded, Factory primer
Educational Facilities
Heavy-duty frames for schools and universities.
- • Abuse resistance
- • Security options
- • Long service life
Config: 16-14 gauge, Welded, Powder coat
Healthcare Facilities
Frames for hospitals and medical clinics.
- • Easy cleaning
- • Lead-lining compatible
- • Automatic operator prep
Config: 16 gauge, Welded, Antimicrobial
Industrial Facilities
Heavy-duty frames for manufacturing and warehouse.
- • Heavy-gauge options
- • Galvanized available
- • Exterior frames
Config: 16-14 gauge, Welded galvanized
Secondary Applications
Hotels
Guest room corridors
Residential
Multi-family stairwells
Government
Security frames
Retail
Back-of-house
Frame Types
Welded Frame
Factory-welded corners with full penetration welds for maximum strength and clean appearance.
Best For: New Construction, Fire-Rated
Knock-Down (KD)
Three-piece frame assembled in the field. Ideal for retrofit projects and existing wall openings.
Best For: Renovation, Retrofit
Drywall Slip-On
Split-jamb frame that clips over finished drywall. Fast installation with no rough opening required.
Best For: Office Interiors
Thermal Break Frame
Frames with thermal isolator for exterior energy efficiency and condensation control.
Double Egress Frame
Frames for double-acting doors in corridors and high-traffic areas.
Construction Details
Anchor Types
- Masonry T-Anchor: For CMU, brick, concrete
- Steel Stud Anchor: Clip anchors for metal studs
- Wood Stud Anchor: Screw anchors for wood studs
- Compression Anchor: For retrofit KD frames
Hardware Reinforcement
- Hinge: 14 gauge (Std) / 7 gauge (Heavy)
- Strike: 16 gauge box / 14 gauge wrap
- Closer: 14 gauge / 12 gauge plate
Corner Construction
Welded Corner
Full mitered weld, ground smooth. Maximum strength equal to parent metal.
KD Corner
Interlocking tab assembly with compression fit. Good strength for standard applications.
Materials & Gauges
Cold-Rolled Steel
Standard steel for interior construction. Smooth finish for painting.
Use: Interior Office, Commercial
Galvanized Steel
Hot-dip galvanized (G90) for maximum exterior corrosion resistance.
Use: Exterior, Corrosive Areas
Gauge Comparison
| Gauge | Thickness | Level | Application |
|---|---|---|---|
| 18 Gauge | 0.048" | Standard | Light Commercial |
| 16 Gauge ★ | 0.060" | Heavy-Duty | Standard Commercial |
| 14 Gauge | 0.075" | Extra Heavy | High-Traffic / Schools |
| 12 Gauge | 0.105" | Maximum | Security / Detention |
Finish Options
Factory Primer
DEFAULTRust-inhibitive shop coat for field painting. Cost-effective standard option.
Factory Powder Coat
DURABLEFactory-applied finish ready for installation. Consistent color and durability.
Galvanized + Powder
Dual protection system for exterior applications. 25+ year life.
Performance Ratings
| Finish | Durability | Exterior | Cost |
|---|---|---|---|
| Primer | Field Finish | No | $ |
| Powder Coat | Good | Limited | $$ |
| Galv + PC | Excellent | Yes | $$$$ |
Technical Specifications
Dimensions
| Parameter | Specification |
|---|---|
| Standard Widths | 2'6", 2'8", 3'0", 3'4", 3'6", 4'0" |
| Standard Heights | 6'8", 7'0", 8'0" |
| Wall Thickness | 4-3/4" to 8-3/4" |
| Max Single | 4'0" x 10'0" |
Performance Specs
| Parameter | Value | Requirement |
|---|---|---|
| Fire Rating | Up to 3 Hours | Complete labeled assembly |
| Structural Abuse | High | Per gauge selection |
| Wind Load | Engineered | For exterior applications |
Standards Compliance
Manufacturing
- • HMMA 820 - Steel Frame Standards
- • SDI-111 - Standard Details
- • AWS D1.3 - Welding Compliance
Testing
- • UL 10B/10C - Fire Test
- • ANSI A250.8 - SDI Specs
- • NFPA 80 - Fire Door Installation
Customization
Profiles & Configurations
- Face Width: 1-3/4" (narrow), 2" (std), 3" (wide)
- Stops: 5/8" integral, adjustable, no stop
- Specialty: Transom, sidelight, borrowed lite
Hardware Prep
- Hinges: 4-1/2" ball bearing, continuous
- Locks: Cylindrical (4-7/8"), Mortise, Electric
- Closers: Surface reinforced, concealed prep
Installation Guidelines
Welded Frame Installation
- Set frame in opening, align anchors.
- Plumb hinge jamb, level head.
- Brace frame to maintain width.
- Grout frame (masonry) or screw anchors (stud).
- Verify square after setting.
KD Frame Installation
- Assemble head and jambs with tabs.
- Set assembly in existing opening.
- Plumb and level using compression anchors.
- Tighten anchors to grip wall.
- Install trim and verify operation.
Fire-Rated Requirements
- • Install per NFPA 80
- • Grouting required for masonry frames
- • Do not modify reinforcement
- • Maintain label visibility
Frequently Asked Questions
Welded vs Knock-Down: Which is better?
What gauge frame should I specify?
Do I need galvanized frames for exterior?
What wall thicknesses are supported?
What is the lead time?
Product Comparison
Metal Frames vs Alternatives
| Feature | Steel Frame | Wood Frame | Aluminum Frame |
|---|---|---|---|
| Fire Ratings | Up to 3 hr | 90 min max | Limited |
| Durability | Excellent | Good | Good |
| Security | Excellent | Moderate | Moderate |
| Cost | $$ | $$ | $$$ |