Product Overview
Euwoo Galvanized Steel Doors are engineered for maximum durability in environments where corrosion resistance is critical. Utilizing hot-dip galvanizing per ASTM A123, these doors provide complete zinc coating coverage, including edges and welds, ensuring superior protection compared to standard steel doors.
From industrial manufacturing facilities and food processing plants to harsh exterior applications, our galvanized doors offer a self-healing barrier against rust and moisture. Available in multiple gauges and with specialized coatings like FDA-compliant finishes, they deliver long-term performance with minimal maintenance.
Applications
Galvanized steel doors for corrosion-critical environments
Industrial Facilities
Withstands industrial conditions with low maintenance requirements.
- • Manufacturing floor & warehouse access
- • Equipment room & loading dock entries
- • Long service life & fire ratings available
Config: 16 gauge, Steel stiffened, Natural galvanized
Food Processing
Meets sanitary requirements with washdown capability.
- • FDA/USDA compliant options
- • Washdown capable & easy to clean
- • Corrosion resistant for cold storage
Config: 18 gauge, Polyurethane, FDA-compliant coating
Exterior Applications
Long-term protection for building entries and service doors.
- • Weather resistance & 25+ year life
- • Self-healing protection against scratches
- • Minimal maintenance required
Config: 18 gauge, Polyurethane, Powder coat over Galv
High-Moisture Areas
Superior corrosion resistance for humidity and water exposure.
- • Pool equipment & water treatment
- • Locker rooms & laundry facilities
- • Mold resistant & no rust
Config: 18 gauge, Galv with powder coat
Secondary Applications
Agricultural
Farm structures
Parking
Garages & enclosed structures
Coastal
Salt air exposure
Chemical
Storage & handling
Key Features
Hot-Dip Galvanized
Complete zinc coating through hot-dip process per ASTM A123 provides superior protection.
Self-Healing Protection
Zinc coating provides cathodic protection, self-healing minor scratches and damage.
Exterior Durability
Engineered for harsh exterior environments to withstand moisture and humidity.
Industrial Performance
Ideal for industrial facilities and food processing where corrosion resistance is critical.
Fire Rating Options
UL-listed fire ratings from 20 to 90 minutes while maintaining galvanized protection.
Finish Flexibility
Natural galvanized appearance or factory-applied powder coat over galvanized.
Material Options
Hot-Dip Galvanized
Steel immersed in molten zinc per ASTM A123. Complete zinc coating with maximum protection.
Use: Exterior, Industrial
Galvanneal
Zinc-iron alloy coating for superior paint adhesion. Best for painted architectural finishes.
Use: Painted Exterior
Pre-Galvanized (G90)
Steel sheet galvanized before fabrication. Economical choice for less demanding areas.
Use: Budget Interior
Grade Comparison
| Property | Hot-Dip Galv | Galvanneal | Pre-Galv G90 |
|---|---|---|---|
| Zinc Coverage | Complete | Complete + Alloy | Sheet only |
| Edge Protection | Excellent | Very Good | Fair |
| Paint Adhesion | Good | Excellent | Good |
| Salt Spray Hours | 1500+ | 1200+ | 500+ |
| Cost Index | $$ | $$ | $ |
Gauge Options
| Gauge | Thickness | Level | Description |
|---|---|---|---|
| 18 Gauge ★ | 1.20mm | Level 2 | Standard commercial galvanized construction. |
| 16 Gauge | 1.50mm | Level 3 | Heavy-duty for demanding industrial environments. |
| 14 Gauge | 1.90mm | Level 4 | Maximum-duty for severe industrial abuse. |
Finish & Coating Options
Natural Galvanized
DEFAULTUncoated zinc finish showing natural spangle. Maximum corrosion protection with no paint maintenance.
Powder Coat over Galv
RECOMMENDEDFactory-applied powder coating over galvanized substrate for dual protection and color. AAMA 2603/2604.
Epoxy Primer System
Chemical-resistant epoxy over galvanized for harsh industrial environments.
Special Coatings
FDA/USDA
Food safe compliance
Chemical Resistant
Lab/Industrial use
Anti-Microbial
Healthcare/Food
High-Temp
Industrial ovens
Technical Specifications
Dimensions
| Parameter | Specification |
|---|---|
| Standard Widths | 2'6", 2'8", 3'0", 3'4", 3'6", 4'0" |
| Standard Heights | 6'8", 7'0", 8'0" |
| Max Single Door | 4'0" x 9'0" (1219mm x 2743mm) |
| Max Pair Doors | 8'0" x 9'0" (2438mm total) |
Core Specifications
| Core Type | R-Value | Fire Rating | Application |
|---|---|---|---|
| Honeycomb | R-2 | 20 min | Standard Interior |
| Polystyrene | R-8-10 | 20 min | Thermal |
| Polyurethane | R-12-15 | 45 min | Exterior / Cold Storage |
| Steel Stiffened | R-1-2 | 3 hours | Fire / Industrial |
Standards Compliance
Galvanizing & Manufacturing
- • ASTM A123 - Hot-Dip Galvanizing
- • ASTM A653 - Galvanized Sheet Steel
- • HMMA 860/861 - Guide Specifications
- • SDI-100 - Steel Door Standards
Testing & Performance
- • ASTM B117 - Salt Spray Testing
- • UL 10B/10C - Fire Testing
- • ASTM E90 - Sound Transmission
Construction & Design
Full-Flush
Smooth, seamless face surfaces galvanized after fabrication. Continuous welded seams.
Seamless
Single sheet face with no vertical seams for enhanced appearance.
Heavy-Duty
Reinforced construction for industrial abuse resistance and forklift traffic.
Galvanized Reinforcement
Full galvanized protection
Extended prep
Through-bolted option
Frame Systems
Galvanized frame solutions for corrosion-resistant assemblies
Galvanized Welded Frame
Factory-welded frames galvanized after fabrication. Full-welded corners ground smooth then galvanized.
- • Complete galvanized coverage
- • No exposed edges
- • Maximum corrosion protection
Pre-Galvanized KD Frame
Knocked-down frame made from pre-galvanized steel. Lower cost, field assembly.
Stainless Steel Frame
304/316 stainless steel for maximum corrosion resistance in marine/chemical areas.
Customization
Vision & Louvers
- Vision Lites: 6x27, 10x10, Full Lite (UL listed galvanized kits)
- Louvers: Inverted Y, V-blade, Fusible link (Fire-rated)
- Material: Galvanized steel to match door
Hardware Prep
- Hinges: Stainless steel or galvanized ball bearing
- Locks: Cylindrical (161), Mortise (86)
- Access: Electric Strike, Mag Lock, Card Reader
Durability & Performance
Corrosion Resistance
Impact Resistance
Product Comparison
Galvanized vs Alternatives
| Feature | Hot-Dip Galv | Paint Only | Stainless | Aluminum |
|---|---|---|---|---|
| Corrosion Protection | Excellent | Fair | Superior | Very Good |
| Self-Healing | Yes | No | N/A | No |
| Edge Protection | Complete | None | Complete | Complete |
| Cost Index | $$ | $ | $$$$ | $$$ |
| Fire Ratings | All available | All available | Limited | Limited |
Installation Guidelines
Pre-Installation Checklist
- Check coating for damage
- Verify plumb and level
- Use stainless fasteners
Installation Steps
- Set frame in opening; shim hinge jamb plumb.
- Secure with galvanized/stainless anchors.
- Hang door using stainless hinges.
- Check clearances (1/8" max).
- Touch-up with cold galvanizing compound.
Fire-Rated Requirements
- • Use only listed galvanized/stainless hardware
- • Maintain maximum 1/8" clearances
- • Self-closing device required
- • Do not modify labeled assembly