Product Overview

Euwoo Galvanized Steel Doors are engineered for maximum durability in environments where corrosion resistance is critical. Utilizing hot-dip galvanizing per ASTM A123, these doors provide complete zinc coating coverage, including edges and welds, ensuring superior protection compared to standard steel doors.

From industrial manufacturing facilities and food processing plants to harsh exterior applications, our galvanized doors offer a self-healing barrier against rust and moisture. Available in multiple gauges and with specialized coatings like FDA-compliant finishes, they deliver long-term performance with minimal maintenance.

Product Overview
1500+
Hours Salt Spray
3 HR
Max Fire Rating
A123
ASTM Standard
30+
Year Lifespan

Applications

Galvanized steel doors for corrosion-critical environments

Industrial Facilities

Withstands industrial conditions with low maintenance requirements.

  • • Manufacturing floor & warehouse access
  • • Equipment room & loading dock entries
  • • Long service life & fire ratings available

Config: 16 gauge, Steel stiffened, Natural galvanized

Food Processing

Meets sanitary requirements with washdown capability.

  • • FDA/USDA compliant options
  • • Washdown capable & easy to clean
  • • Corrosion resistant for cold storage

Config: 18 gauge, Polyurethane, FDA-compliant coating

Exterior Applications

Long-term protection for building entries and service doors.

  • • Weather resistance & 25+ year life
  • • Self-healing protection against scratches
  • • Minimal maintenance required

Config: 18 gauge, Polyurethane, Powder coat over Galv

High-Moisture Areas

Superior corrosion resistance for humidity and water exposure.

  • • Pool equipment & water treatment
  • • Locker rooms & laundry facilities
  • • Mold resistant & no rust

Config: 18 gauge, Galv with powder coat

Secondary Applications

Agricultural

Farm structures

Parking

Garages & enclosed structures

Coastal

Salt air exposure

Chemical

Storage & handling

Key Features

Hot-Dip Galvanized

Complete zinc coating through hot-dip process per ASTM A123 provides superior protection.

Self-Healing Protection

Zinc coating provides cathodic protection, self-healing minor scratches and damage.

Exterior Durability

Engineered for harsh exterior environments to withstand moisture and humidity.

Industrial Performance

Ideal for industrial facilities and food processing where corrosion resistance is critical.

Fire Rating Options

UL-listed fire ratings from 20 to 90 minutes while maintaining galvanized protection.

Finish Flexibility

Natural galvanized appearance or factory-applied powder coat over galvanized.

Material Options

Recommended

Hot-Dip Galvanized

Steel immersed in molten zinc per ASTM A123. Complete zinc coating with maximum protection.

Use: Exterior, Industrial

Galvanneal

Zinc-iron alloy coating for superior paint adhesion. Best for painted architectural finishes.

Use: Painted Exterior

Pre-Galvanized (G90)

Steel sheet galvanized before fabrication. Economical choice for less demanding areas.

Use: Budget Interior

Grade Comparison

Property Hot-Dip Galv Galvanneal Pre-Galv G90
Zinc Coverage Complete Complete + Alloy Sheet only
Edge Protection Excellent Very Good Fair
Paint Adhesion Good Excellent Good
Salt Spray Hours 1500+ 1200+ 500+
Cost Index $$ $$ $

Gauge Options

Gauge Thickness Level Description
18 Gauge ★ 1.20mm Level 2 Standard commercial galvanized construction.
16 Gauge 1.50mm Level 3 Heavy-duty for demanding industrial environments.
14 Gauge 1.90mm Level 4 Maximum-duty for severe industrial abuse.

Finish & Coating Options

Natural Galvanized

DEFAULT

Uncoated zinc finish showing natural spangle. Maximum corrosion protection with no paint maintenance.

Powder Coat over Galv

RECOMMENDED

Factory-applied powder coating over galvanized substrate for dual protection and color. AAMA 2603/2604.

Epoxy Primer System

Chemical-resistant epoxy over galvanized for harsh industrial environments.

Finish Samples

Special Coatings

FDA/USDA

Food safe compliance

Chemical Resistant

Lab/Industrial use

Anti-Microbial

Healthcare/Food

High-Temp

Industrial ovens

Technical Specifications

Dimensions

ParameterSpecification
Standard Widths2'6", 2'8", 3'0", 3'4", 3'6", 4'0"
Standard Heights6'8", 7'0", 8'0"
Max Single Door4'0" x 9'0" (1219mm x 2743mm)
Max Pair Doors8'0" x 9'0" (2438mm total)

Core Specifications

Core Type R-Value Fire Rating Application
Honeycomb R-2 20 min Standard Interior
Polystyrene R-8-10 20 min Thermal
Polyurethane R-12-15 45 min Exterior / Cold Storage
Steel Stiffened R-1-2 3 hours Fire / Industrial

Standards Compliance

Galvanizing & Manufacturing
  • • ASTM A123 - Hot-Dip Galvanizing
  • • ASTM A653 - Galvanized Sheet Steel
  • • HMMA 860/861 - Guide Specifications
  • • SDI-100 - Steel Door Standards
Testing & Performance
  • • ASTM B117 - Salt Spray Testing
  • • UL 10B/10C - Fire Testing
  • • ASTM E90 - Sound Transmission

Construction & Design

Standard

Full-Flush

Smooth, seamless face surfaces galvanized after fabrication. Continuous welded seams.

Seamless

Single sheet face with no vertical seams for enhanced appearance.

Heavy-Duty

Reinforced construction for industrial abuse resistance and forklift traffic.

Galvanized Reinforcement

Hinge Area 12 gauge (Std) / 7 gauge (Heavy)
Full galvanized protection
Lock Area 14 gauge (Std) / 12 gauge (Heavy)
Extended prep
Closer Area 14 gauge backing
Through-bolted option

Frame Systems

Galvanized frame solutions for corrosion-resistant assemblies

Recommended

Galvanized Welded Frame

Factory-welded frames galvanized after fabrication. Full-welded corners ground smooth then galvanized.

  • • Complete galvanized coverage
  • • No exposed edges
  • • Maximum corrosion protection
Use Case Exterior, Industrial, Moisture

Pre-Galvanized KD Frame

Knocked-down frame made from pre-galvanized steel. Lower cost, field assembly.

Stainless Steel Frame

304/316 stainless steel for maximum corrosion resistance in marine/chemical areas.

Customization

Vision & Louvers

  • Vision Lites: 6x27, 10x10, Full Lite (UL listed galvanized kits)
  • Louvers: Inverted Y, V-blade, Fusible link (Fire-rated)
  • Material: Galvanized steel to match door

Hardware Prep

  • Hinges: Stainless steel or galvanized ball bearing
  • Locks: Cylindrical (161), Mortise (86)
  • Access: Electric Strike, Mag Lock, Card Reader

Durability & Performance

Corrosion Resistance

Hot-Dip Galvanized: 1500+ hours salt spray
Galv + Powder: 2500+ hours salt spray
Mechanism: Barrier & Cathodic Protection

Impact Resistance

18 Gauge (Level 2): Standard Commercial
16 Gauge (Level 3): Heavy Industrial
14 Gauge (Level 4): Forklift / Severe

Product Comparison

Galvanized vs Alternatives

Feature Hot-Dip Galv Paint Only Stainless Aluminum
Corrosion Protection Excellent Fair Superior Very Good
Self-Healing Yes No N/A No
Edge Protection Complete None Complete Complete
Cost Index $$ $ $$$$ $$$
Fire Ratings All available All available Limited Limited

Installation Guidelines

Pre-Installation Checklist

  • Check coating for damage
  • Verify plumb and level
  • Use stainless fasteners

Installation Steps

  1. Set frame in opening; shim hinge jamb plumb.
  2. Secure with galvanized/stainless anchors.
  3. Hang door using stainless hinges.
  4. Check clearances (1/8" max).
  5. Touch-up with cold galvanizing compound.

Fire-Rated Requirements

  • • Use only listed galvanized/stainless hardware
  • • Maintain maximum 1/8" clearances
  • • Self-closing device required
  • • Do not modify labeled assembly

Frequently Asked Questions

Hot-dip vs Pre-galvanized: What's the difference?
Hot-dip galvanizing involves immersing the completed door in molten zinc, providing complete coverage including edges/welds. Pre-galvanized (G90) is sheet galvanized before fabrication, leaving cut edges unprotected. Hot-dip is superior for exterior/industrial use.
How long will galvanized doors last?
Hot-dip galvanized doors typically last 25-30 years in exterior applications. With powder coat finish, life can extend to 30+ years. Regular maintenance helps achieve maximum life.
Can galvanized doors be painted?
Yes. For factory finishing, galvanneal steel offers best adhesion. Hot-dip galvanized requires surface prep. We recommend factory powder coating for best results.
Are they suitable for food processing?
Yes. For direct food contact or FDA compliance, we recommend galvanneal steel with FDA-compliant powder coat finishes and stainless steel hardware.
What is the lead time?
Standard galvanized doors ship in 4-5 weeks due to the galvanizing process. Pre-galvanized (G90) can ship in 3-4 weeks. Custom sizes require 6-8 weeks.

Get Started with Your Project

Request a quote or speak with our technical team

Request Quote

Submit specifications for competitive factory-direct pricing.

Request Quote

Download Specs

Get complete technical specifications and CAD files.

Download Specs

Technical Support

Our team can help with galvanizing and corrosion specs.

+86 152 3616 2255

technical@euwoo.com

ASTM A123 Compliant
UL and WHI Certified
FDA-Compliant Finishes
20+ Years Experience