UL/BS/CE Certified

FIRE-RATED DOOR
MANUFACTURER

Complete range of fire-rated doors with 30 to 120 minute ratings. Steel, wooden, and glass fire doors certified to UL 10C, BS 476-22, EN 1634-1, and GB 12955 standards. Factory-direct pricing for commercial projects.

30-120 Minute Fire Ratings
4 Material Options
15-30 Days Lead Time
50+ Countries Exported
UL
Listed
CE
Marked
BS 476
ISO 9001
GB 12955
Product Range

FIRE DOORS BY MATERIAL

Choose from multiple material options to match your project requirements and aesthetic preferences

Steel Fire-Rated Door
Most Popular

Steel Fire-Rated Doors

Heavy-duty steel construction for maximum fire protection in commercial and industrial settings. Cold-rolled steel with mineral core, available in all fire ratings up to 120 minutes.

30 min 60 min 90 min 120 min
View Details
Wooden Fire Door
Aesthetic Choice

Wooden Fire Doors

Natural wood aesthetics with fire protection. Ideal for hotels, offices, and residential.

30-90 min
View Details →
Glass Fire Door
Modern Design

Glass Fire Doors

Maximum natural light and visibility with fire-rated glazing. Modern architectural style.

30-90 min
View Details →
Stainless Steel Fire Door
Corrosion Resistant

Stainless Steel Fire Doors

304/316 grade stainless steel for environments requiring corrosion resistance and hygiene. Ideal for food processing, pharmaceutical facilities, and marine applications.

30 min 60 min 90 min 120 min
View Details
Fire Protection Levels

FIRE DOORS BY RATING DURATION

Select the appropriate fire rating based on building code requirements and fire compartmentation needs

Specialized Solutions

FIRE DOORS BY APPLICATION

Specialized fire door solutions designed for specific building types and industry requirements

Commercial Fire Doors
Business Ready

Commercial Fire Doors

Fire-rated doors designed for commercial building requirements including offices, retail, and mixed-use developments.

  • • Code-compliant specifications
  • • Multiple finish options
  • • Hardware compatibility
Learn More →
Industrial Fire Doors
Heavy Duty

Industrial Fire Doors

Robust fire doors for manufacturing facilities, warehouses, and industrial environments.

  • • Heavy-gauge steel construction
  • • Impact-resistant design
  • • Forklift-traffic rated
Learn More →
Hospital Fire Doors
Healthcare Certified

Hospital Fire Doors

Fire doors meeting strict healthcare facility requirements including wide openings and quiet operation.

  • • Wide openings for gurneys
  • • Antimicrobial finishes
  • • Silent closure mechanisms
Learn More →
Fire Door Frames
Complete Systems

Fire Door Frames

Certified fire-rated door frames designed to match our fire door products for complete systems.

  • • Matched fire ratings
  • • Welded or knocked-down
  • • Pre-machined for hardware
Learn More →

Not Sure Which Fire Door Is Right for Your Project?

Our technical team can help you select the right fire door based on your building code requirements, fire rating needs, and application specifications.

Understanding Fire Door Ratings

Fire door ratings indicate the duration a door assembly can withstand fire exposure while maintaining its integrity. Choose the right rating based on your building code requirements.

Key Terms

  • Fire Resistance Rating

    Time duration a door can withstand fire exposure without failure.

  • Fire Protection Rating

    Duration a door prevents fire and smoke spread through an opening.

  • Temperature Rise Rating

    Max temperature increase on unexposed side during fire testing.

Get Rating Recommendation

30 Minute (FD30)

Residential

Entry-level fire protection providing essential fire compartmentation for residential and light commercial applications.

Integrity: 30 min minimum

IBC: Required for 1-hour fire partitions

Most Common

60 Minute (FD60)

Commercial

The most commonly specified fire rating for commercial buildings worldwide. Standard for corridors and fire compartments.

Integrity: 60 min minimum

IBC: Required for 1-hour fire barriers

90 Minute (FD90)

High-Rise

Enhanced fire protection for high-rise buildings and critical escape routes. Required for stairwell enclosures in tall buildings.

Integrity: 90 min minimum

IBC: Required for 2-hour fire barriers

120 Minute (FD120)

Critical

Maximum fire protection for critical fire barriers and high-risk facilities. Essential for occupancy separations.

Integrity: 120 min minimum

IBC: Required for 3-hour fire walls

International Fire Testing Standards

UL 10C North America
BS 476-22 United Kingdom
EN 1634-1 Europe (CE)
GB 12955 China
AS 1530.4 Australia/NZ
Material Selection

Fire Door Material Comparison

Compare the characteristics of different fire door materials to select the best option for your application requirements

Property Steel Wood Glass Stainless Steel
Max Fire Rating 120 min 90 min 90 min 120 min
Durability Excellent (5/5) Good (3/5) Good (3/5) Excellent (5/5)
Aesthetics Industrial (3/5) Natural (5/5) Modern (5/5) Professional (4/5)
Weight Heavy Medium Heavy Heavy
Cost $$ (Best Value) $$$ $$$$ $$$$$
Maintenance Low Medium Low Very Low
Corrosion Resistance Fair N/A Good Excellent
Best For Commercial, Industrial, High-traffic Hotels, Offices, Residential Modern buildings, Retail, Lobbies Food, Pharma, Marine, Chemical

General Commercial

Budget-conscious projects needing reliable performance

Recommend: Steel

Hotels & Upscale Offices

Aesthetic priority with adequate fire protection

Recommend: Wood

Modern Architecture

Maximum visibility and contemporary appearance

Recommend: Glass

Food, Pharma, Marine

Corrosive environments and hygiene requirements

Recommend: Stainless
Industry Solutions

Fire Door Applications by Industry

Our fire-rated doors serve diverse building types and industries, each with specific fire protection requirements

Commercial Buildings

Office buildings, retail centers, and mixed-use developments requiring 60-90 minute fire protection.

  • Corridor doors
  • Stairwell enclosures
  • Tenant separations
  • Elevator lobbies
Code: IBC Chapter 7, NFPA 101

Healthcare Facilities

Hospitals and clinics with gurney-width openings, infection control, and quiet operation requirements.

  • Patient corridors
  • Operating suites
  • Smoke compartments
  • Pharmaceutical areas
Code: NFPA 101 Chapter 18/19

Industrial Facilities

Heavy-duty fire doors for manufacturing, warehouses, and food processing with impact resistance.

  • Production areas
  • Hazardous storage
  • Food processing
  • Control rooms
Code: IBC Chapter 4, NFPA 30

Educational Institutions

Schools and universities balancing fire safety with high-traffic durability and security.

  • Corridor doors
  • Classroom exits
  • Dormitory corridors
  • Laboratory areas
Code: NFPA 101 Chapter 14/15

Hospitality

Hotels and venues with aesthetic standards and guest comfort including quiet operation.

  • Guest room corridors
  • Stairwells
  • Meeting rooms
  • Kitchen separations
Code: NFPA 101 Chapter 28/29

High-Rise Buildings

Most stringent requirements due to extended evacuation times and critical compartmentation.

  • 90-min stairwell doors
  • Elevator lobbies
  • Mechanical floors
  • Refuge areas
Code: IBC Section 1023
Manufacturer Advantage

WHY CHOOSE EUWOO FIRE DOORS

International certifications with factory-direct efficiency to deliver reliable fire protection solutions

20+ Years Manufacturing Experience
50+ Countries Exported
4 International Certifications
15-30 Days Standard Lead Time

International Certifications

UL, BS 476, CE, and GB 12955 certified. One manufacturer, multiple market certifications for global project compliance.

  • • UL listed for North American projects
  • • BS 476 certified for UK and Middle East
  • • CE marked for European Union

Factory-Direct Manufacturing

Direct supply from our Luoyang facility eliminates distributor margins. ISO 9001 certified quality at competitive prices.

  • • Direct manufacturer-to-project supply
  • • ISO 9001:2015 certified production
  • • 2000+ units/month capacity

Full OEM/ODM Capabilities

Custom specifications for your project requirements. Non-standard dimensions, special finishes, and project-specific labeling.

  • • Custom door sizes within tested limits
  • • Special surface finishes and coatings
  • • Private labeling programs

Complete Door Systems

Matched door, frame, and hardware assemblies. Complete systems tested together for proper fire rating compliance.

  • • Fire-rated doors with certified frames
  • • Pre-machined for specified hardware
  • • Single-source warranty

Efficient Lead Time

15-30 day standard lead time for most orders. Expedited production available for urgent project requirements.

  • • 15-30 days standard production
  • • Expedited options available
  • • Global shipping coordination

Technical Support

Engineering guidance from specification to installation. Code consultation and certification documentation support.

  • • Code compliance consultation
  • • Certification documents for submittals
  • • Installation guidance

Euwoo vs. Typical Fire Door Options

Feature Euwoo Direct Trading Company Local Distributor
Certifications UL + BS + CE (Factory-held) Varies (Third-party sourced) Limited selection
Pricing Factory-direct pricing Factory + trading margin Factory + trading + distribution
Customization Full OEM/ODM capability Limited (depends on factory) Minimal customization
Quality Control In-house ISO 9001 QC Factory-dependent Receiving inspection only
Technical Support Direct engineering access Relayed support Limited technical depth
Lead Time 15-30 days standard Varies widely Stock-dependent
Quality Assurance

INTERNATIONAL CERTIFICATIONS

Our fire-rated doors are tested and certified to meet international fire safety standards for global project compliance

UL

UL Listed

UL 10C Standard

Underwriters Laboratories certification for North American building code compliance.

Region: USA, Canada
BS

BS 476 Certified

BS 476-22 Standard

British Standard fire resistance certification for UK and Commonwealth markets.

Region: UK, Middle East, GCC
CE

CE Marked

EN 1634-1 Standard

European CE marking for free movement within the European Economic Area.

Region: European Union
ISO

ISO 9001:2015

Quality Management

International quality management system certification for consistent product quality.

Region: International

Project Compliance Support

Fire Test Reports

Complete test reports for project submittals

Code Consultation

Technical guidance on fire door requirements

Project Labeling

Project-specific labels for inspection

Installation Docs

Detailed installation instructions

Fire Door Customization

Beyond standard specifications, we offer comprehensive customization to meet your project's unique requirements while maintaining full fire rating compliance.

All customizations are designed by our engineering team to maintain certified fire performance.

Submit Custom Specifications

Dimensional Options

  • • Custom width and height within fire rating test limits
  • • Door thickness options: 45mm, 50mm, 55mm
  • • Custom frame depths for specific wall constructions
  • • Equal or unequal double door configurations

Surface Finishes

  • • Powder coating: RAL color palette + custom colors
  • • Wood veneer: Oak, Maple, Walnut, Cherry, custom species
  • • HPL laminate patterns and colors
  • • Stainless steel: #4 Brushed, #8 Mirror, PVD coating

Vision Panels & Glazing

  • • Standard sizes: 300×300mm, 200×600mm
  • • Custom sizes within fire-rated glass limits
  • • Clear, tinted, frosted, wire-free options
  • • Custom positioning for accessibility

Hardware Preparation

  • • Hinge: Standard and custom locations/sizes
  • • Locks: Cylindrical, mortise, electric strikes
  • • Closers: Surface, concealed, floor closer prep
  • • Exit devices: Rim, mortise, vertical rod prep

Minimum Order Quantities

20 units Standard specs
50 units Custom sizes
100 units Custom finishes
200 units Private labeling
Common Questions

Fire-Rated Door FAQs

Common questions about fire door specifications, certifications, and procurement

A fire door rating indicates how long the door assembly can withstand fire exposure during standardized testing. For example, a 60-minute fire door has been tested and certified to maintain structural integrity, prevent flame passage, and limit temperature rise for at least 60 minutes. The rating represents the minimum protection time, giving building occupants time to evacuate safely.

Fire door ratings are typically determined by building codes based on the fire resistance rating of the wall where the door is installed. The general rule is that fire door ratings are 75% of the wall rating (e.g., 90-minute door in a 2-hour wall). Requirements depend on building type, height, occupancy classification, and door location. Always verify with your local building authority.

We provide comprehensive certification documentation including: fire test reports from accredited laboratories, certification listing documents (UL, BS, CE as applicable), Declaration of Performance (DoP) for CE marked products, fire door labels with traceability information, and installation instructions. All documents are available in electronic format for project submittals.

Yes, fire doors must be installed in compatible fire-rated frames to maintain the fire rating of the assembly. The door and frame work together as a system - a fire door in a non-rated frame will not provide proper fire protection. We supply complete door and frame assemblies tested together, ensuring the entire assembly maintains its fire rating.

Standard lead time for fire doors is 15-30 days from order confirmation, depending on quantity, specifications, and customization requirements. Expedited production is available for urgent projects at additional cost. We recommend early engagement for projects with specific timeline requirements to ensure production capacity allocation.

Minimum order quantities vary: Standard fire doors with common specifications: 20 units. Custom sizes within tested limits: 50 units. Custom finishes (powder coating, wood veneer): 100 units. Private labeling OEM programs: 200 units. Contact our sales team to discuss specific requirements - we can often accommodate smaller quantities for initial orders.

READY TO SPECIFY FIRE-RATED DOORS?

Get certified fire doors with factory-direct pricing and international compliance documentation. Our team responds within 24 business hours.

UL/BS/CE Certified
Factory-Direct Pricing
Full Customization
15-30 Day Lead Time

Contact us directly:

Sales: sales@euwoo.com Technical: technical@euwoo.com Hours: Mon-Fri 8:00-18:00 CST