Complete range of fire-rated doors with 30 to 120 minute ratings. Steel, wooden, and glass fire doors certified to UL 10C, BS 476-22, EN 1634-1, and GB 12955 standards. Factory-direct pricing for commercial projects.
Choose from multiple material options to match your project requirements and aesthetic preferences
Heavy-duty steel construction for maximum fire protection in commercial and industrial settings. Cold-rolled steel with mineral core, available in all fire ratings up to 120 minutes.
Natural wood aesthetics with fire protection. Ideal for hotels, offices, and residential.
Maximum natural light and visibility with fire-rated glazing. Modern architectural style.
304/316 grade stainless steel for environments requiring corrosion resistance and hygiene. Ideal for food processing, pharmaceutical facilities, and marine applications.
Select the appropriate fire rating based on building code requirements and fire compartmentation needs
Entry-level fire protection for residential and light commercial applications.
Most commonly specified rating for commercial buildings worldwide.
Enhanced fire protection for high-rise buildings and critical escape routes.
Maximum fire protection for critical fire barriers and high-risk facilities.
Specialized fire door solutions designed for specific building types and industry requirements
Fire-rated doors designed for commercial building requirements including offices, retail, and mixed-use developments.
Robust fire doors for manufacturing facilities, warehouses, and industrial environments.
Fire doors meeting strict healthcare facility requirements including wide openings and quiet operation.
Certified fire-rated door frames designed to match our fire door products for complete systems.
Our technical team can help you select the right fire door based on your building code requirements, fire rating needs, and application specifications.
Fire door ratings indicate the duration a door assembly can withstand fire exposure while maintaining its integrity. Choose the right rating based on your building code requirements.
Time duration a door can withstand fire exposure without failure.
Duration a door prevents fire and smoke spread through an opening.
Max temperature increase on unexposed side during fire testing.
Entry-level fire protection providing essential fire compartmentation for residential and light commercial applications.
Integrity: 30 min minimum
IBC: Required for 1-hour fire partitions
The most commonly specified fire rating for commercial buildings worldwide. Standard for corridors and fire compartments.
Integrity: 60 min minimum
IBC: Required for 1-hour fire barriers
Enhanced fire protection for high-rise buildings and critical escape routes. Required for stairwell enclosures in tall buildings.
Integrity: 90 min minimum
IBC: Required for 2-hour fire barriers
Maximum fire protection for critical fire barriers and high-risk facilities. Essential for occupancy separations.
Integrity: 120 min minimum
IBC: Required for 3-hour fire walls
Compare the characteristics of different fire door materials to select the best option for your application requirements
| Property | Steel | Wood | Glass | Stainless Steel |
|---|---|---|---|---|
| Max Fire Rating | 120 min | 90 min | 90 min | 120 min |
| Durability | Excellent (5/5) | Good (3/5) | Good (3/5) | Excellent (5/5) |
| Aesthetics | Industrial (3/5) | Natural (5/5) | Modern (5/5) | Professional (4/5) |
| Weight | Heavy | Medium | Heavy | Heavy |
| Cost | $$ (Best Value) | $$$ | $$$$ | $$$$$ |
| Maintenance | Low | Medium | Low | Very Low |
| Corrosion Resistance | Fair | N/A | Good | Excellent |
| Best For | Commercial, Industrial, High-traffic | Hotels, Offices, Residential | Modern buildings, Retail, Lobbies | Food, Pharma, Marine, Chemical |
Budget-conscious projects needing reliable performance
Recommend: SteelAesthetic priority with adequate fire protection
Recommend: WoodMaximum visibility and contemporary appearance
Recommend: GlassCorrosive environments and hygiene requirements
Recommend: StainlessOur fire-rated doors serve diverse building types and industries, each with specific fire protection requirements
Office buildings, retail centers, and mixed-use developments requiring 60-90 minute fire protection.
Hospitals and clinics with gurney-width openings, infection control, and quiet operation requirements.
Heavy-duty fire doors for manufacturing, warehouses, and food processing with impact resistance.
Schools and universities balancing fire safety with high-traffic durability and security.
Hotels and venues with aesthetic standards and guest comfort including quiet operation.
Most stringent requirements due to extended evacuation times and critical compartmentation.
International certifications with factory-direct efficiency to deliver reliable fire protection solutions
UL, BS 476, CE, and GB 12955 certified. One manufacturer, multiple market certifications for global project compliance.
Direct supply from our Luoyang facility eliminates distributor margins. ISO 9001 certified quality at competitive prices.
Custom specifications for your project requirements. Non-standard dimensions, special finishes, and project-specific labeling.
Matched door, frame, and hardware assemblies. Complete systems tested together for proper fire rating compliance.
15-30 day standard lead time for most orders. Expedited production available for urgent project requirements.
Engineering guidance from specification to installation. Code consultation and certification documentation support.
| Feature | Euwoo Direct | Trading Company | Local Distributor |
|---|---|---|---|
| Certifications | UL + BS + CE (Factory-held) | Varies (Third-party sourced) | Limited selection |
| Pricing | Factory-direct pricing | Factory + trading margin | Factory + trading + distribution |
| Customization | Full OEM/ODM capability | Limited (depends on factory) | Minimal customization |
| Quality Control | In-house ISO 9001 QC | Factory-dependent | Receiving inspection only |
| Technical Support | Direct engineering access | Relayed support | Limited technical depth |
| Lead Time | 15-30 days standard | Varies widely | Stock-dependent |
Our fire-rated doors are tested and certified to meet international fire safety standards for global project compliance
UL 10C Standard
Underwriters Laboratories certification for North American building code compliance.
Region: USA, CanadaBS 476-22 Standard
British Standard fire resistance certification for UK and Commonwealth markets.
Region: UK, Middle East, GCCEN 1634-1 Standard
European CE marking for free movement within the European Economic Area.
Region: European UnionQuality Management
International quality management system certification for consistent product quality.
Region: InternationalComplete test reports for project submittals
Technical guidance on fire door requirements
Project-specific labels for inspection
Detailed installation instructions
Beyond standard specifications, we offer comprehensive customization to meet your project's unique requirements while maintaining full fire rating compliance.
All customizations are designed by our engineering team to maintain certified fire performance.
Submit Custom SpecificationsCommon questions about fire door specifications, certifications, and procurement
A fire door rating indicates how long the door assembly can withstand fire exposure during standardized testing. For example, a 60-minute fire door has been tested and certified to maintain structural integrity, prevent flame passage, and limit temperature rise for at least 60 minutes. The rating represents the minimum protection time, giving building occupants time to evacuate safely.
Fire door ratings are typically determined by building codes based on the fire resistance rating of the wall where the door is installed. The general rule is that fire door ratings are 75% of the wall rating (e.g., 90-minute door in a 2-hour wall). Requirements depend on building type, height, occupancy classification, and door location. Always verify with your local building authority.
We provide comprehensive certification documentation including: fire test reports from accredited laboratories, certification listing documents (UL, BS, CE as applicable), Declaration of Performance (DoP) for CE marked products, fire door labels with traceability information, and installation instructions. All documents are available in electronic format for project submittals.
Yes, fire doors must be installed in compatible fire-rated frames to maintain the fire rating of the assembly. The door and frame work together as a system - a fire door in a non-rated frame will not provide proper fire protection. We supply complete door and frame assemblies tested together, ensuring the entire assembly maintains its fire rating.
Standard lead time for fire doors is 15-30 days from order confirmation, depending on quantity, specifications, and customization requirements. Expedited production is available for urgent projects at additional cost. We recommend early engagement for projects with specific timeline requirements to ensure production capacity allocation.
Minimum order quantities vary: Standard fire doors with common specifications: 20 units. Custom sizes within tested limits: 50 units. Custom finishes (powder coating, wood veneer): 100 units. Private labeling OEM programs: 200 units. Contact our sales team to discuss specific requirements - we can often accommodate smaller quantities for initial orders.
Still have questions?
Contact our technical team: technical@euwoo.comGet certified fire doors with factory-direct pricing and international compliance documentation. Our team responds within 24 business hours.
Contact us directly: