Heavy-Duty

INDUSTRIAL
FIRE DOORS

Heavy-duty fire-rated doors built for industrial environments. Factories, warehouses, process areas, and manufacturing plants. Oversized options and 60-120 minute ratings.

60-120
Minutes
Fire Rating Range
14 ga
Steel
Heavy Construction
20-35
Days
Lead Time
3m+
Height
Oversized Available
60-120 Min UL/BS/CE Industrial Grade Oversized Factory Direct
UL 10C Listed
FM Approved
CE EN 1634-1
BS 476:22
GB 12955

Key Features

Fire protection engineered for industrial demands

14 Gauge Steel

Heavy-Gauge Construction

14 and 16 gauge steel construction for maximum durability. Built to withstand forklift traffic, industrial abuse, and harsh operating conditions.

  • Industrial durability
  • Impact resistance
  • Long service life
Up to 120 Min

60-120 Minute Ratings

Higher fire ratings for industrial applications. Protects process areas, hazardous storage, and provides fire barriers in large manufacturing facilities.

  • Process protection
  • Hazardous areas
  • Code compliance
Custom Sizes

Oversized Options

Fire-rated doors available in heights exceeding 3 meters and widths up to 2.4 meters. Custom sizes for industrial openings.

  • Equipment access
  • Forklift clearance
  • Industrial openings
Galv/SS Options

Corrosion Resistant

Galvanized steel or stainless steel options for chemical plants, food processing, and corrosive environments.

  • Chemical resistance
  • Humidity tolerance
  • Extended life
HD Hardware

Industrial Hardware

Heavy-duty hinges, panic hardware, and closers rated for industrial door weights and high-frequency operation.

  • Cycle tested
  • Heavy-duty operation
  • Reliable performance
UL/BS/CE/GB

Industrial Certifications

UL 10C, BS 476-22, EN 1634-1, and GB 12955 certified. Documentation for industrial facility permits.

  • Global compliance
  • Facility permits
  • Insurance acceptance

Note: Industrial fire doors are purpose-built for the demanding environments of factories, warehouses, and manufacturing facilities.

Industrial Fire Door Construction

Heavy-duty construction for demanding industrial environments

Industrial fire doors require substantially more robust construction than commercial doors to withstand the abuse of manufacturing and warehouse environments. Key differences include heavier gauge steel, reinforced internal structures, impact-resistant design, and heavy-duty hardware mounting provisions.

Industrial Focus: Heavy-gauge steel construction with reinforcement for forklift impact, high cycling, and harsh conditions.

Heavy-Gauge Steel Fire Doors Standard Industrial

Steel fire doors with heavier gauge skins and enhanced reinforcement are the standard for industrial environments. Construction is significantly more robust than commercial steel doors to handle forklift traffic, equipment impact, and high-cycle operation.

Skins: 16-14 gauge galvanized
Core: 160-250 kg/m³ mineral wool
Reinforcement: Full internal
Edges: Welded or heavy-duty
Advantages
  • Maximum impact resistance
  • Handles forklift abuse
  • High cycle capability (1,000,000+ cycles)
  • All fire ratings available (60-120 minute)
Best For
Warehouse fire walls Manufacturing Loading docks
Lead Time: 20-35 days $$-$$$
Stainless Steel Industrial Corrosive/Hygiene

Stainless steel construction for industrial environments where corrosion resistance, chemical exposure, or sanitation requirements demand more than galvanized steel. Common in food processing, pharmaceutical, and chemical industries.

Skins: SS 304/316
Gauge: 16 gauge min
Core: High-density mineral wool
Edges: Fully welded SS
Advantages
  • Corrosion resistance for wet/chemical environments
  • Sanitary surfaces for food/pharma
  • Easy to clean and sanitize
Best For
Food processing Pharmaceutical Chemical facilities
Lead Time: 25-40 days $$$$
Industrial Sliding Fire Doors Large Openings

Horizontal sliding fire doors for large industrial openings where swing doors are impractical. Common for vehicle access, large equipment transfer, and loading dock separations. Operate on overhead track with fire-release mechanism.

Skins: 14-16 gauge min
Core: High-density mineral wool
Operation: Gravity-close or motor
Track: Heavy-duty overhead
Advantages
  • Covers very large openings (up to 10m+ wide)
  • No swing clearance required
  • Single or bi-parting configurations
  • Motor operation for frequent use
Best For
Large equipment transfer Vehicle access Loading dock separations
Lead Time: Project-specific $$$$-$$$$$

Steel Gauge Selection for Industrial Applications

Gauge Thickness (mm) Application Impact Resistance
18 gauge 1.2mm NOT recommended for industrial Low
16 gauge 1.5mm Standard industrial duty Moderate
14 gauge 2.0mm Heavy industrial duty Good
12 gauge 2.7mm Maximum industrial duty Excellent

Recommendation: 16 gauge minimum for general industrial; 14 gauge for forklift areas and high-abuse environments.

Industrial vs. Commercial Construction

Aspect Commercial Industrial Note
Steel Gauge 18-16 gauge 16-14 gauge Industrial heavier
Reinforcement Standard internal Full internal structure Industrial fully reinforced
Core Density 120-160 kg/m³ 160-250 kg/m³ Denser industrial cores
Edge Construction Standard interlocking Welded or heavy-duty Industrial for impact
Frame Gauge 16-18 gauge 14-12 gauge Heavier industrial frames
Cycle Rating 500,000 cycles 1,000,000+ cycles Industrial higher cycle

Industrial Fire Door Ratings

Fire protection levels for manufacturing and warehouse environments

Industrial facilities require fire doors designed for harsh environments and heavy use. Fire rating requirements depend on building construction type, fire compartment requirements, and specific industrial hazards. Most industrial applications are served by 60 or 90-minute fire doors.

Industrial Focus: Rating selection based on fire compartment requirements, hazard classification, and insurance considerations.

60
Minutes
Standard Industrial Rating

The baseline fire rating for most industrial fire compartmentation. Adequate protection for standard manufacturing and warehousing where hazardous materials are minimal.

Typical Applications
  • • Warehouse fire compartments
  • • Manufacturing floor separations
  • • Loading dock separations
  • • Office-to-warehouse separations
90
Minutes
Enhanced Industrial Protection

Required for larger fire compartments, high-hazard areas, or where insurance requirements mandate enhanced protection. Common in high-rack storage facilities.

Typical Applications
  • • High-rack warehouse separations
  • • Large fire compartment boundaries
  • • High-value manufacturing areas
  • • FM Global-compliant installations
120
Minutes
Maximum Industrial Protection

The highest standard rating, specified for critical industrial separations, hazardous materials storage, and facilities requiring maximum fire containment.

Typical Applications
  • • Hazardous materials storage
  • • Petrochemical compartmentation
  • • Critical infrastructure protection
  • • High-risk process separations

Industrial Fire Rating Comparison

Factor 60 Minutes 90 Minutes 120 Minutes
Industrial Use STANDARD Enhanced/FM Global High-Hazard/Critical
Typical Application General industrial Large compartments H-occupancy
Cost $$ $$$ $$$$
Availability Excellent Good Moderate
Door Weight ~50-55kg ~65kg ~75-85kg
Material Options All All (wood max) Steel/SS only

Typical Ratings by Industrial Facility Type

General Manufacturing (F-1/F-2)

Fire compartment walls, Stairwells, Office separation

60-minute standard

Warehouse/Distribution (S-1/S-2)

Fire compartment walls, High-rack area separation

60-90 minute (90 for high-rack)

High-Hazard Manufacturing (H)

H-occupancy separations, Control room, Storage areas

90-120 minute per H-occupancy code

Food Processing

Processing area separations, Warehouse, Cooler/freezer

60-minute (consider stainless steel)

FM Global Requirements

FM Global-insured facilities often have enhanced fire door requirements. FM Global may require ratings above building code minimum. Consult FM Global Data Sheets and verify requirements with insurance representative early in design.

Technical Specifications

Technical specifications for manufacturing and warehouse applications

Industrial Door Dimensions

Type Width Height Use
Single Doors
Personnel 900mm (3'-0") 2100mm (7'-0") Personnel doors
Standard Industrial 1000mm (3'-4") 2100mm (7'-0") Standard industrial personnel
Wide Personnel 1200mm (4'-0") 2400mm (8'-0") Wide personnel/small equipment
Double Doors
Standard Pair 1800mm (6'-0") 2100mm (7'-0") Personnel/small equipment pairs
Equipment Access 2000mm (6'-8") 2400mm (8'-0") Equipment access pairs
Large Equipment 2400mm (8'-0") 2700mm (9'-0") Large equipment access
Vehicle/Large 3000mm (10'-0") 3000mm (10'-0") Vehicle/large equipment pairs

Industrial Construction Specifications

Standard Industrial Duty

Personnel doors, office separation, light industrial

  • Thickness: 50-60mm
  • Skin Gauge: 18 gauge (1.2mm) min
  • Core: 120-160 kg/m³
  • Reinforcement: Standard

Heavy Industrial Duty

RECOMMENDED for most industrial

  • Thickness: 60-70mm
  • Skin Gauge: 16 gauge (1.5mm) min
  • Core: 160-200 kg/m³
  • Reinforcement: Full internal

Maximum Industrial Duty

Forklift areas, extreme abuse, high-security

  • Thickness: 70-80mm
  • Skin Gauge: 14 gauge (2.0mm) min
  • Core: 200+ kg/m³
  • Reinforcement: Enhanced structure

Industrial Hardware Specifications

Component Industrial Spec Industrial Note
Hinges Heavy-duty ball bearing, Grade 1 (3 min; 4-5 for heavy/large) Grease-able for dusty environments
Door Closer Industrial-grade surface-mounted, EN 5-6 minimum Heavy-duty closer essential
Lockset Heavy-duty cylindrical or mortise lock Consider keypad/card for secure areas
Exit Device Heavy-duty rim or vertical rod panic hardware Required for high-occupancy industrial areas
Threshold Heavy-duty aluminum or steel threshold Flush threshold for equipment traffic

Performance Requirements

60-90 min
Fire Resistance
Standard; 120 for high-hazard
Level C
Impact Resistance
Maximum duty for forklift areas
1M+
Cycle Rating
High-cycle for industrial
Grade III
Abuse Resistance
SDI 115 Extra Heavy Duty
≤3.0 CFM
Smoke Control
UL 1784 per sq ft
Galv/SS
Corrosion
Environment-specific

Industrial Protection Accessories

Kickplate

10"-16" height, 14 gauge steel or 1/8" aluminum

Protection from foot traffic and equipment

Full-Height Armor Plate

Stainless steel or aluminum sheet

Maximum protection for forklift impact

Crash Rails

Heavy-gauge steel rails at forklift height

Deflect forklift impact from door

Edge Guards

Steel or stainless edge protectors

Protect door edges from cart/equipment

Corner Guards

Reinforced corner protectors

Protect door corners from impact

Bollards

Concrete-filled steel bollards

Protect door opening from vehicle impact

Note: Protection accessories significantly extend door life in industrial environments.

Applications

Fire protection for industrial facilities

Manufacturing Plants

Process area separations, control room access, hazardous process areas, and fire barriers in manufacturing facilities.

90 min 120 min
Key Requirements
  • • Oversized options
  • • Heavy-duty construction
  • • Corrosion resistance
Warehouses & Distribution

Fire compartmentalization in large warehouses, loading dock separations, and storage area protection.

60 min 90 min
Key Requirements
  • • Forklift impact resistance
  • • Large openings
  • • High traffic durability
Chemical & Petrochemical

Control rooms, process area separations, hazardous material storage, and safety critical applications.

90 min 120 min
Key Requirements
  • • Chemical resistance
  • • Stainless steel
  • • Maximum ratings
Power & Utilities

Transformer rooms, generator enclosures, cable tunnels, and electrical equipment protection.

90 min 120 min
Key Requirements
  • • Electrical room rated
  • • Heavy gauge
  • • Reliable operation

Industrial Fire Code Requirements

Industrial facilities have specific fire separation requirements based on hazard classification, building size, and stored materials. FM Global and other insurers may have additional requirements beyond code minimum.

Contact Euwoo for industrial fire door specification assistance.

Industrial Fire Door Certifications

Standards and compliance for industrial facility applications

Industrial fire doors must meet fire testing standards, building codes, and often additional requirements from insurance carriers and industry-specific regulations. FM Global approval is frequently required for insured industrial facilities.

Industrial Focus: Industrial certifications often include FM Global approval and industry-specific compliance beyond standard fire ratings.

Primary Certifications

UL UL 10C Fire Performance

The primary fire door test standard for industrial construction in North America. All fire doors in industrial facilities must be UL Listed or equivalent.

Code Ref: IBC, NFPA 80, OSHA
Label: Door edge (hinge side)
60 min 90 min 120 min
FM FM Approved

FM Global certification provides additional assurance for property loss prevention. Many FM Global-insured facilities require FM Approved fire doors.

FM Approval Types:
  • • FM Class 4400 - Fire Doors
  • • FM Class 4410 - Fire Door Frames
  • • FM Class 4420 - Fire Door Hardware

Key specification requirement for industrial projects

NFPA 80 Compliance

NFPA 80 governs installation, inspection, testing, and maintenance of fire doors. Industrial facilities must maintain NFPA 80-compliant inspection programs.

Requirements
  • • Labeled door and frame assemblies
  • • Annual inspection program
  • • Documentation of inspections and repairs
  • • Self-closing and positive-latching operation
OSHA Compliance

OSHA regulations reference fire doors in industrial facilities, particularly for exit routes and hazardous materials handling.

Regulations: 29 CFR 1910.36-37, 1910.106
Requirements
  • • Fire doors properly rated and labeled
  • • Self-closing mechanisms functional
  • • No blocked or propped-open fire doors

International Industrial Certifications

Certification Region Ratings Industrial Relevance
EN 1634-1 European Union EI60, EI90, EI120 Industrial facilities in EU; export manufacturing
BS 476: Part 22 UK / International FD60, FD90, FD120 UK industrial facilities; Middle East, Commonwealth
GB 12955 China Grade A, Grade B Industrial facilities in China
AS 1905.1 Australia/NZ -/60/90/120 Industrial facilities in Australia/New Zealand

FM FM Global Approval Details

What is FM Approval?

Third-party certification that products meet FM Global property loss prevention standards.

Why is it Important?

FM Global-insured facilities often require FM Approved products for full coverage.

How to Verify?

Check FM Approvals Guide (online) for listed products and limitations.

Beyond UL Listing

FM Approval may include additional testing beyond UL 10C requirements.

Always verify FM Approval status for FM Global-insured industrial facilities

Euwoo Industrial Fire Door Certifications

Our Certifications
  • • UL 10C Listed (60, 90, 120-minute)
  • • FM Approved (select products)
  • • BS 476: Part 22 (FD60-FD120)
  • • EN 1634-1 (EI60-EI120)
  • • GB 12955 (Grade A, B)
Industrial Capabilities
  • • FM Approved products for insured facilities
  • • Documentation packages for permit and insurance
  • • Project-specific compliance letters
  • • Technical support for industrial applications

Industrial Fire Door Installation

Installation requirements for manufacturing and warehouse environments

Industrial fire door installation requires consideration of heavy door weights, oversized openings, harsh environments, and ongoing operational requirements. Unlike commercial installations, industrial doors often cannot interrupt facility operations during installation.

Industrial Focus: Heavy-duty installation methods, minimal operational disruption, coordination with plant operations.

Pre-Installation Requirements

Operational Coordination

  • • Coordinate with plant operations schedule
  • • Plan during scheduled downtime when possible
  • • Arrange temporary fire protection if removing existing doors
  • • Notify facility fire marshal of installation schedule

Site Access and Logistics

  • • Plan delivery route for heavy doors and frames
  • • Arrange forklift or crane access for heavy/oversized doors
  • • Clear staging area for door storage
  • • Verify floor load capacity for heavy equipment

Structural Verification

  • • Verify wall can support heavy door and frame weight
  • • Confirm anchor points engage structural elements
  • • For metal building, verify girt locations
  • • Consider structural engineer review for oversized openings

Component Verification

  • • Verify doors and frames match approved submittals
  • • Check construction grade matches specification
  • • Confirm fire labels indicate correct rating
  • • Verify all hardware is fire-rated and industrial-grade

Frame Installation Steps

1

Position Heavy-Duty Frame

Set industrial-grade frame (14 gauge minimum) in prepared opening. Use heavy-duty shims. Industrial frames are significantly heavier—use appropriate handling equipment.

2

Verify Frame for Industrial Load

Confirm frame is rated for industrial door weight and expected abuse. 14 gauge minimum for standard industrial; 12 gauge for maximum duty.

3

Industrial Anchoring

Secure frame using appropriate anchors for wall construction type. 5-6 anchors per jamb for heavy industrial. Use expansion or epoxy anchors for concrete, T-anchors for CMU.

4

Grout Frame Completely

Fill hollow steel frames completely with grout or dense mineral fill. Industrial doors are heavier—complete grouting is even more critical. No voids permitted.

5

Industrial Perimeter Sealing

Apply fire-rated sealant around entire frame perimeter. For industrial environments, consider enhanced sealant for dust, moisture, or chemical exposure.

Door Installation Steps

1

Mount Heavy-Duty Hinges

4 hinges minimum for standard, 5 for heavy/tall doors. Use Grade 1 heavy-duty ball bearing hinges.

2

Hang Door with Equipment

Industrial doors 60-85+ kg require mechanical lifting. NEVER attempt manual lift of industrial fire doors.

3

Verify Industrial Clearances

Head/jambs: max 3mm. Bottom: max 19mm. Industrial floors may be uneven—verify at multiple points.

4

Install Industrial Closer

EN 5-6 or higher industrial-grade closer. Adjust for reliable closing against air pressure differentials.

5

Install Protection Accessories

Mount kickplates, armor plates, edge guards, crash rails before door is in regular use.

6

Final Testing

Test self-closing from fully open. Confirm positive latching. Test under actual operating conditions.

Common Industrial Installation Mistakes

Using commercial-grade frame/hardware

Causes premature failure under industrial use

Insufficient anchoring

Frame loosening, door misalignment over time

Using standard closer (EN 3-4)

Closer fails to close door reliably; premature failure

Incomplete frame grouting

Fire rating compromised; frame damage under impact

Industrial Fire Door Maintenance

Task Frequency Items to Check
Operational Check Weekly to Monthly Door closes properly, latches securely, closer operates
Visual Inspection Monthly Impact damage, seal condition, hardware security
Comprehensive Inspection Quarterly Full inspection, clearances, all components
Annual Inspection Annual (NFPA 80) Documented inspection by qualified inspector
Hinge Lubrication Quarterly (dusty) Lubricate ball bearing hinges per manufacturer

Industrial Fire Door Customization

Configure fire doors for manufacturing and warehouse requirements

Industrial fire doors offer customization focused on durability, operational requirements, and facility-specific conditions. Unlike commercial projects where aesthetics may drive decisions, industrial customization prioritizes function, durability, and long-term performance.

Industrial Focus: Customization driven by operational requirements, abuse levels, and environmental conditions.

Construction Grade

Select based on abuse level

  • Standard Industrial 16 gauge
  • Heavy Industrial 14 gauge ★
  • Maximum Industrial 12-14 gauge
Door Material

Material for industrial environment

  • Galvanized Steel $$
  • Stainless Steel 304 $$$$
  • Stainless Steel 316 $$$$$
Door Dimensions

Standard and oversized options

  • Personnel Doors 900-1200mm
  • Industrial Pairs 1800-2400mm
  • Oversized 3000mm+
Finish Options

Industrial finish selections

Industrial Grey Anthracite Safety Yellow Safety Orange Safety Red Custom RAL
Vision Panels

Fire-rated glazing options

  • Small (150-200mm) All ratings
  • Standard (200-500mm) 60-90 min
  • Wire Glass Impact resistant
Protection Accessories

Impact protection options

  • • Standard Kickplate (8"-12")
  • • Extended Kickplate (16"-36")
  • • Full-Height Armor
  • • Crash Rails
  • • Edge Guards / Corner Guards

Pre-Configured Industrial Packages

Standard Industrial

General industrial personnel doors

  • • 16 gauge steel
  • • Galvanized + powder coat
  • • Standard prep
  • • Intumescent seal

Warehouse Heavy-Duty

RECOMMENDED

  • • 14 gauge steel
  • • Full reinforcement
  • • Vision panel
  • • 12" kickplate + smoke seal

Forklift Area

Maximum protection

  • • 14 gauge maximum reinforcement
  • • Full armor plate
  • • Edge guards
  • • Crash rail provision

Food Processing

Hygienic construction

  • • Stainless steel 304
  • • Hygienic construction
  • • Easy-clean seals
  • • Smooth surfaces

Industrial Order Process

1 Site Assessment (1-3 days)
2 Specification (2-3 days)
3 Quotation (2-3 days)
4 Shop Drawings (3-5 days)
5 Manufacturing (20-35 days)
6 QC & Delivery

Industrial Fire Door Comparison

Compare options for manufacturing and warehouse applications

Industrial Construction Grade Comparison

Factor Standard Industrial Heavy Industrial Maximum Industrial
Steel Gauge 16 gauge (1.5mm) 14 gauge (2.0mm) 12-14 gauge (2.0-2.7mm)
Internal Reinforcement Standard Full reinforcement Maximum reinforcement
Impact Resistance Good Very Good Excellent
Forklift Suitability Limited Good Excellent
Cycle Rating 500,000+ 1,000,000+ 1,000,000+
Cost $$ $$$ $$$$
Best Application Personnel doors Warehouse general Forklift/high-abuse

Recommendation: Heavy Industrial is recommended for most warehouse and manufacturing applications.

Industrial Material Comparison

Factor Galvanized Steel Stainless Steel 304 Stainless Steel 316
Cost $$ $$$$ $$$$$
Corrosion Resistance Good Very Good Excellent
Chemical Resistance Moderate Good Excellent
Hygiene/Cleanability Moderate Excellent Excellent
Impact Resistance Excellent Good Good
Best Application General industrial Food/pharma Chemical/coastal

Recommendation: Galvanized steel for general industrial; stainless for corrosive or hygienic environments.

Industrial vs. Commercial Fire Doors

Factor Commercial Industrial Note
Steel Gauge 16-18 gauge typical 14-16 gauge minimum Industrial heavier
Primary Concern Cost, aesthetics Durability, impact Different priorities
Forklift Traffic Not suitable Designed for it Key industrial requirement
Cycle Rating 500,000 cycles 1,000,000+ cycles Industrial higher capacity
Reinforcement Standard Full internal structure Industrial more robust
Frame Construction 16-18 gauge 14-12 gauge welded Industrial heavier
Cost $-$$ $$-$$$ Industrial premium for durability

Always specify industrial-grade doors for manufacturing and warehouse applications—commercial doors will fail prematurely.

Recommended Configuration by Application

General Manufacturing

Grade: Heavy Industrial
Material: Galvanized Steel
Rating: 60-minute
Accessories: Standard kickplate

Warehouse Fire Walls

Grade: Heavy Industrial
Material: Galvanized Steel
Rating: 60-90 minute
Accessories: Vision panel, kickplate, edge guards

Forklift Traffic Areas

Grade: Maximum Industrial
Material: Galvanized Steel
Rating: 60-90 minute
Accessories: Full armor, crash rails, edge guards

Food Processing

Grade: Heavy Industrial
Material: Stainless Steel 304
Rating: 60-minute
Accessories: Easy-clean seals

Chemical Processing

Grade: Heavy Industrial
Material: Stainless Steel 316
Rating: 90-120 minute
Accessories: Chemical-resistant coating

High-Rack Warehouse

Grade: Heavy Industrial
Material: Galvanized Steel
Rating: 90-minute (FM Global)
Accessories: Standard industrial

Industrial Fire Door Investment Summary

Heavy-duty construction

Significantly longer service life in industrial environment. Lower total cost of ownership.

Protection accessories

Prevents door replacement from impact damage. Pays for itself after first avoided replacement.

Stainless steel (where needed)

Eliminates corrosion replacement in harsh environments. Essential for corrosive/hygienic environments.

FM Approved products

Insurance compliance, potential premium reduction. Required for full coverage; may reduce premiums.

Industrial fire doors cost more upfront but provide significantly better ROI through extended service life, reduced maintenance, and avoided replacement costs.

Frequently Asked Questions

Common questions about industrial fire doors

Q What gauge steel should I specify for industrial fire doors?

14 gauge is recommended for most industrial applications. It provides superior impact resistance, longer service life, and better performance under industrial abuse. 16 gauge is suitable for lighter-duty industrial areas.

Q Can industrial fire doors accommodate forklift traffic?

Yes, heavy-gauge construction and proper kick plates can handle forklift impact. Consider power operators for high-frequency forklift traffic areas. Install bollards or guards for added protection.

Q What's the maximum size for industrial fire-rated doors?

Single doors up to 1400mm x 3000mm (55" x 118") with proper engineering. Double doors can span larger openings. Oversized doors may require special frames and multiple hinges.

Q Are galvanized fire doors available?

Yes, G90 galvanized steel fire doors are available for humid, wet, or mildly corrosive environments. For aggressive chemicals, stainless steel 304 or 316 grade is recommended.

Q What is the lead time for industrial fire doors?

20-35 days for standard industrial sizes. Oversized or custom configurations may require additional time. Contact Euwoo for project scheduling.

Get Your Industrial Fire Door Quote

Heavy-duty fire protection for industrial facilities

Planning an Industrial Project?

Get competitive factory-direct pricing on heavy-duty fire doors for factories, warehouses, and manufacturing facilities. Oversized options and industrial specifications.

  • Oversized capabilities
  • Heavy-gauge construction
  • Industrial specifications
  • Volume pricing
Request Quote
UL/BS/CE Certified
International compliance
14 Gauge Steel
Heavy-duty construction
20-35 Day Lead Time
Industrial production
Technical Support
Industrial expertise

Related Products